Set the CT coil's parameters locally using
the Configuration Manager of the wallbox.
See chapter Configure the Audi Wallbox
plus and Audi Wallbox pro locally for more
information.
Note: Any different configuration than the
ones presented above is considered invalid
and causes an error state.
Ground Loss Mo-
nitor Enabled
Ground Loss Mo-
nitor Disabled
Group B: Scaling current
NOTE: If the wallbox does
not have a CT coil attached
(indicated by DIP-switch
setting of group A =
0000x), then the scaling
current is the maximum
static current of the
station.
32
Group A switches
1
2
N/A
N/A
N/A
N/A
N/A
N/A
NOTE: If the wallbox does
have a CT coil attached,
which is set by DIP-switch
group A, then the scaling
current is the maximum
facility current per phase.
Ground loss monitor configuration
DIP-switch 5, in group A configures the functio-
nality of the ground loss monitor. By default, this
feature is enabled from the factory.
NOTE: The wallbox will not detect a
ground connection if the ground loss mo-
nitoring functionality is disabled.
3
4
5
N/A
0
N/A
1
Illustration
NOTE: If the static max
current is set above the
station rating, an error
will be shown and the
wallbox will be inoperable.