Wired Controller CDV 57
② When two wired controllers control one water tank or hot water generator,
the addresses of those two wired controllers should be different. Please refer
to 3.2.2 Parameter Setting.
③ When two wired controllers control multiple water tanks or hot water
generators simultaneously, they can connect to any one water tank or hot
water generator, but the connected ones must be either water tanks or hot
water generators. The addresses of those two wired controllers should be
different. Please refer to 3.2.2 Parameter Setting. The total quantity of water
tank or hot water generator controlled by wired controller can't exceed 3 sets,
and the connected water tank or hot water generator must be within the
same network.
④ When one (or two) wired controller(s) control (s) multiple water tanks or hot
water generators at the same time, the controlled water tanks or hot water
generators should have the same setting.
⑤ Network connection of wired controller and water tank or hot water
generator must be according to one of the four wiring methods as shown in
fig 3.4-3.7 As for the connection method shown in fig 3.5 and 3.7, there
should be only one master wired controller (address is 01) and one slave
wired controller (address 02). The quantity of wired controller can't exceed
two.