temperature zone;
(2)Press "▲" or "▼" button to select parameter code. Press "MODE" button to
enter parameter setting. At that time, parameter value is blinking. Press "▲" or
"▼" button to adjust the parameter value and press "ENTER/CANCEL" button
to finish setting.
(3)Press "ENTER/CANCEL" button to return to last step until system exists
setting parameters.
The parameter setting list is as following:
Parameter
Parameter name
code
Set address of wired
P13
controller
Set quantity of group
P14
controlled water tank
or hot water generator
Table 3.2 Parameter setting list
Parameter range
01: master wired
controller
02: slave wired controller
00: it is prohibited to use
this function
01-03: quantity of water
tank or hot water
generator
19
Wired Controller CDV 57
Default
value
When two wired controllers
control one (or more) water
tank(s) or hot water
generator(s), the addresses
of the two wired controllers
01
should be different. Slave
wired controller (02) is without
unit parameter setting
function except setting its
address.
Set corresponding value
according to the quantity of
01
connected water tanks or hot
water generators
Note