between water temperature setting and actual water temperature. The water tank/hot
water generator will be stopped 1~4 hour after the preset time. After started, the
machine will run cyclically every day.
Night hot water mode: Fix the time of hot water supply at 00:00~06:00, so that the
water tank/hot water generator will be started in this time section. The start / stop of
the compressor is decided according to the difference between preset water
temperature and actual water temperature. If exceeding this time section, the water
tank/hot water generator will be stopped. After started, the machine will run cyclically
every day.

4.4 Water Heating Temperature Setting

When water heating is on, press the "▲" or "▼" button, the set temperature will
increase or decrease by 1℃; when long-pressing the button, the temperature will
increase or decrease by 1℃ every 0.3s.
In the standard water heating mode, preset water heating mode and night water
heating mode, the set temperature ranges from 35℃ to the maximum available
temperature of the water heating.
Note:
① The maximum available temperature of the water heating is considered as
55 , which can be set to 55
② The temperature of standard water heating, preset water heating and night
water heating enjoys the same set range, and the set values of the water
temperature under different modes are independent;
to 70