11
TECHNICAL SPECIFICATIONS
11
Technical specifications
Sensing range
Sensing range max.
Light spot diameter/distance
Supply voltage U
B
Output current I
max.
Switching frequency
Max. response time
Enclosure rating
Protection class
Circuit protection
Ambient operating temperature
en
1)
Limit value; residual ripple max. 5 V
2)
Object with 90 % remission (based on standard white DIN 5033)
2)
With light / dark ratio 1:1
3)
Signal transit time with resistive load
4)
A = U
-connections reverse polarity protected
B
C = Interference suppression
D = outputs overcurrent and short-circuit protected
11.1
Dimensional drawing
12
O P E R A T I N G I N S T R U C T I O N | GSE2 Flat Side
ss
10
(0.39)
Ø 2.2
5.5
5.5
(0.09)
(0.22)
(0.22)
2.2
Ø 2.3
Ø 2.3
(0.09)
(0.09)
(0.09)
Figure 10: GSE2F
Optical axis, receiver
1
Optical axis, sender
2
GSE2F(S)-Xxx11
GSE2F(S)-Xxx21
0 ... 40 mm
0 ... 150 mm
0 ... 60 mm
0 ... 200 mm
see chapter"Light
see chapter"Light
spot diameter"
spot diameter"
DC 10 ... 30 V
DC 10 ... 30 V
1)
≤ 50 mA
≤ 50 mA
800 Hz
800 Hz
2)
≤ 0.625 ms
≤ 0.625 ms
3)
IP67
IP67
III
III
A, C, D
4)
A, C, D
-20 °C ... +50 °C
-20 °C ... +50 °C
2.2
3.5
(0.14)
(0.09)
Figure 11: GSE2FS
1
2
GSE2F(S)-Xxx51
0 ... 500 mm
0 ... 700 mm
see chapter"Light
spot diameter"
DC 10 ... 30 V
1)
1)
≤ 50 mA
800 Hz
2)
2)
≤ 0.625 ms
3)
3)
IP67
III
4)
A, C, D
4)
-20 °C ... +50 °C
11
(0.43)
2.2
(0.09)
2.2
(0.09)
Ø 2.3
(0.09)
Optical axis, receiver
Optical axis, sender
8023329.1C14/28.06.2021 | SICK
Subject to change without notice
4.5
(0.18)