done manually.
② "Start time" and "End time" will be memorized upon power failure
③ It can be set under both ON and OFF states
2.2.16 Floor Debug
This function will make the unit to perform periodic preheating to the floor for the initial run once
floor coils have been installed.
[Operation Instructions]
1. At the homepage, by pressing the Function key
locate where "Floor debug" is, after that, press OK key
page.
2. At the FLOOR DEBUG setting page, by the Left/Right key
parameter and then by the Up/Down key
"Segments", "Period 1 temp", "ΔT of segment", and "Segment time", as listed in the following
table.
No.
Full Name
1
Segments for floor debug
2
First temperature for floor debug
Segment temperature difference for
3
floor debug
4
Segments duration for floor debug
3. After the above setting is finished, by pressing the function key no.2
and a dialog box will pop up, reminding "Start the Floor Debug Mode now?". If so, press the "OK"
key
. Once "Floor debug" has been activated, by pressing the function key no.2
box also will pop up, reminding "Stop the Floor Debug Mode now?" If so, press the OK key
not, press "Cancel"
[Notes]
① This function can be activated only when the unit is OFF. When it is intended to activate this
function with the unit being ON, a dialog box will pop up, warning "Please turn off the system first!".
② When this function has been activated, it is unable to turn on or off the unit. In this case,
Displayed
Name
Segments
Period 1 temp
ΔT of segment
Segment time
to go on.
access to the FUNCTION page, and then
to go to the FLOOR DEBUG setting
configure it. The configurable parameters include
Range
1~10
25~35°C/77~95°F
0~72H
2~10°C/36~50°F
16
Operation Instructions
select the desired
Default
Accuracy
1
1
25°C/77°F
1°C/1°F
0
12H
5°C/41°F
1°C/1°F
activate this function
, a dialog
; if