"Please turn off the system first!"
⑦ Under the Emergency mode, "Floor debug", "Sanitize", "Holiday mode", cannot be
activated, or a dialog box will pop up, warning " Please disable the Emergency Mode!".
⑧ Upon power failure, the "Emergen. mode" will be defaulted to be "Off".

2.2.18 Holiday Mode

In winter or low-temperature season, this function will control the leaving water temperature or
room temperature within a certain range to avoid the water system from being frozen when the user
is out on holiday for a long time.
[Operation Instructions]
1. Locate where "Holiday mode" at the Parameter Set page
2. Set Holiday to "On" or "Off" by the Up/Down key
[Notes]
① At the holiday mode, "Mode" setting of the control and On/Off key operation both are
disabled.
② When it is activated, "Weekly timer", "Clock timer" or "Temp timer" will be deactivated.
③ At the holiday mode, when "T-Room" is adopted, the temperature set point should be 15 ;
when "T-Out water" is adopted, then the temperature set point should be 30 .
④ It will quit when the thermostat effectively works ("Cool" or "OFF" operation).
⑤ When this setting is saved successfully, it will be memorized upon power failure.
⑥ This function can be activated only at the "Heat" mode and with the unit turned off. When it is
done with the unit turned on, a prompt dialog box will pop up, warning "Please turn off the system
first!"; or when it is done at other modes except the "Heat" Mode with the unit turned off, also a
prompt dialog box will pop up, warning "Wrong running mode!".
⑦ When it is activated, the ON/OFF key
warning "Please disable the Holiday Mode !".
⑧ Under the Holiday mode, "Floor debug", "Sanitize", "Emergen. mode" cannot be activated,
or a dialog box will pop up, warning "Please disable the Holiday Mode !".
2.2.19 Thermostat
When the thermostat has been installed, it can be used to control the run mode of the unit (only
"Heat"or "Cool"mode)
[Operation Instructions]
1. Locate where "Thermostat" is at the FUNCTION page
2. By pressing the Up/Down key
the control follows the running mode of the thermostat and is not allowed to set the running mode;
when it is "Off", the control follows the running mode set by itself.
[Notes]
① When "Floor debug" or "Emergen. Mode" is activated, then the control will not receive
signals from the thermostat.
② If "Thermostat" is set to "On", the control will automatically disable some functions concerning
timer, and run in accordance with the mode set by the thermostat. In this case, the running mode is
unchangeable and the ON/OFF key
③ When this setting is saved successfully, it will be memorized upon power failure.
④ The state of the Thermostat can be changed when the unit is turned off.
operation is disabled, or a dialog box will pop up,
, Thermostat can be set to "On" or "Off". When it is "On",
operation of the control is ineffective.