2.2.1 Mode
It enables the user to select the run mode of the unit. When the water tank is not prepared, then
only Cool and Heat modes are available. When the water tank has been prepared and Water Tank is
set to "With" through the wired controller (see Section 2.2.26 for more details), then Cool, Heat, Hot
water, Heat + hot water, and Cool + hot water modes are available. In this case, Heat + hot water
or Cool + hot water can be given priority. (see Section 2.2.5 and 2.2.6 for more details), which is the
default setting before delivery.
[Operation Instructions]
At the equipment OFF state, access to the FUNCTION page and then move through the Left/
Right key
the cursor to the "Mode" whose characters will be reversed, then press the Up/
Down key
to modify its setting.
[Notes]
① The "Heat" mode is defaulted when the unit is energized for the first time.
② The running mode is allowed to be changed only when the unit is not in operation. If it is done
with the unit being on, a window will pop up, warning "Please turn off the system first".
③ When the water tank is disabled, only the 'Heat" or the "Cool" mode is allowed.
④ When the water tank is enabled, "Cool", "Heat", "Hot water", "Cool+hot waterr", "Heat+hot
water" is allowed.
⑤ For the heat pump, the "Cool" mode is allowed; for the heating only unit, "Cool+ Hot water"
and "Cool" are unallowable.
⑥ This setting can be memorized upon power failure.
2.2.2 Control State (Ctrl. state)
It enables the user to configure the control state to leaving water temperature or room
temperature.
[Operation Instructions]
Plate heater
Solar antifre
Water tank
With/Without
Tank sensor
Solar heater
With/Without
Floor config
With/Without
Radia config
With/Without
FCU
With/Without
Remote sensor
With/Without
Air removal
Address
[127~253]
Gate-Controller
On/Off
On
On/Off
Off
Without
1/2
2
Without
Off
Off
Without
Without
On/Off
Off
[0~12]
0
On/Off
Off
6
Operation Instructions
/
When the water tank is unavailable,
this function will be reserved. and
the LCD will display 'Reserved'.
/
If "Floor config" is set to "With", the
control is defaulted to be "Normal
temp". If not, then the control is
defaulted to be "High temp".
When it is set to "Without", the
"Control state" will be automatically
changed to "T-water out".
/
/
/