Ikegami ICD-879 Manual De Instrucciones página 16

Ocultar thumbs Ver también para ICD-879:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

⑤ MANUAL
With this, Rate of Sensitivity Up is fixed with the shutter.
This may be favourably used under the stable lighting condition.
*Note: The same level of screen noise and blurr may be the same even in all three
mode of S/N, STD or MOVE, if the Sensitivity Up was set at its maximum
level.
(2) After selecting the preferable mode,
push E button. Then, the scrren as right
will appear and the setting for Day/Night
selection and On/Off selection of Flicker
Free mode.
* Flicker Free function does not work
when Sens.Up is set at OFF.
If you want to use Flicker Free function,
set 1/100 in SHUTTER setting mode.
(3) DAY/NIGHT
With the L and R buttons, make the AUTO,
COLOR or B/W (Monochrome) setting.
① AUTO
Automatic switching is made: high-
quality color images during the day,
and high-sensitivity monochrome
pictures at night. Press the E button,
and the screen at right shows up.
• B/W BURST
The burst signal in Monochrome
(B/W) pictures can be selected ON
or OFF.
• SW LEVEL
The brightness level for switching
to the day or night mode can be
preset. With L and R button, the
levels can be selected in the order
of BRIGHT, MID and DARK.
The following screen appears, when selected MANUAL.
The thresh-hold can be set to change from color to monochrome picture,
or visa versa.
        SENS UP
 DAY/NIGHT     AUTO
 FLICKER LESS  OFF
      RET   EXIT
       DAY/NIGHT
 B/W BURST  ON
 SW LEVEL   MID
      RET   EXIT
       DAY/NIGHT
 B/W BURST  OFF
 SW LEVEL   MANUAL
 COL→B/W    L・・・I・・・・H
                X12
 B/W→COL    L・・・I・・・・H
                X2
      RET   EXIT