Ikegami ICD-879 Manual De Instrucciones página 24

Ocultar thumbs Ver también para ICD-879:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

(8) MONITOR
By L or R button, picture reproduction mode of monitor can be selected.
① CRT
CRT is for Cathode Ray Tube(Blaun Tube) type monitors.
② LCD
LCD is for FDP, Flat Display Panel type monitors, such as LCD or Plasma.
(9) P.MASK
With E button, Privacy masking (P.Mask,
hereafter) control mode is available.
P.MASK can be set maximum 8 (eight)
points.
① Set to make it active (valid) or not.
By using U or D button, choose
desire Mask number/s, and make it
valid or invalid by L button for ON
(valid) or R button for OFF (invalid).
② Setting of Masking Area
The screen like the one on right
appears by E button after choosing
ON by L and R button.
1) Masking Area Size Change
Move a cursor by Arrow mark, and
use U or D button to move upper
or lower change. Or use L or R
button to move right or left
change.
2) Masking Area reposition
Move a cursor to MOV and push E button. Whole mask can be repositioned
by buttons, U, D, R or L.
Push E button to set a position and return to P.MASK area set screen.
3) DEF
This is for controlling the mask size, or to initialize a position.
4) DISP
This shows the Mask which was set valid. DIPS stands for Display.
5) RET
To return to Mask Set Screen.
③ PAINT
With L or R button, desired color for P.Mask can be selected.
(Black, White or Gray)
      PRIVACY MASK
 MASK1  OFF  MASK5  OFF
 MASK2  OFF  MASK6  OFF
 MASK3  OFF  MASK7  OFF
 MASK4  OFF  MASK8  OFF
      PAINT  GRAY
       RET   EXIT
           ↑
       ←  MOV  →
           ↓
    RET   DEF   DISP
E-21

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido