(9) Privacy Masking Function
The ICD-879 comes equipped with privacy masking, which covers sensitive
areas in the screen that need to remain unseen. You can assign a maximum of
8 zones with minimum 8 pixel square sized area to hide with this masking
function for a pin-point accuracy by the rear panel control switches, or remotely
over RS-485 link. The RCU-801 remote setup and control unit can perform the
same function.
(10)Lens flange back focus adjustment
An easy adjustment can be done by a rotating disk mechanism and convenient
side access port-side Lock screw. This may be useful when changing lens
from single focal lens, vari-focal lens, long focal lens, or zoom lenses, or vice
versa.
(11) Optimum Monitor Output Select function
The optimum picture quality can be obtained with this unique function for CR
or LCD monitors. Sometimes, LCD, Liquid Crystal display type, Flat Screen
Monitor with digital process function shows different display reproduction
characteristics and you may choose this output selection to have the best
pictures on the monitor screen.
(12)Remote or Local camera setup and parameter memory function
ICD-879 series camera comes equipped with micro-chip controlled camera
setup and memory function as a standard provision. Camera setup can be
easily done locally with control switches on the camera rear panel using OSD,
On Screen Display, or remotely by I-LAN, Ikegami's camera control software
over RS-485 link. In addition, an optional remote setup and control unit, such
as the RCU-801 can be used for this purpose via coaxial video cable connection.
(13)Focus EZ function
The auto iris lens aperture will be kept open. Even in broad daylight, the focus
is readily adjustable no matter how much the depth of field is.