Device elements
Illustration on the inside of the front
cover
1 Guiding rolls with fixed position brake
2 Drain hose
3 Marking maximum filling level, red
4 Push handle
5 Power cord
6 Suction head
7 ON/OFF switch
8 Suction hose connection
9 Lock
10 Deflector plate
11 Liquid reservoir
12 Accessories compartment
13 Unlocking lever
14 Tilting chassis
Illustration on the inside of the front
cover
Bring the appliance to working position
- secure it, if required, with parking
brakes.
Ensure that the suction head has been
fitted properly.
Illustration
Insert the suction hose into the suction
hose connection.
Attach the desired accessories to the
suction hose.
Operation
Illustration on the inside of the front
cover
Insert the mains plug into the socket.
Illustration
Turning on the Appliance
Start suction process.
Note: When vacuuming up fluids, only im-
merse the accessories half way in order to
deliver sufficient air.
12
Start up
Check the fill level display
Note: The red marking on the drain hose
shows the maximum admissible filling lev-
el.
Empty the liquid container.
Note: If the device is full, the mechanical
filling level switch-off terminates the vacu-
uming operation.
Switch off the appliance and remove
the plug from the socket.
Drive the appliance to the disposal site
for the liquid.
Disconnect the drain hose at the upper
hose coupling.
Hold the drain hose over a suitable col-
lection unit and drain the content.
Dispose of the contents according to
the local provisions.
EN
– 3