Installing the plant
Only for authorised technicians!
!
Assembly
ATTENTION
Always keep the installation site of the system well ven-
tilated to protect the machine against over-heating.
–
The appliance should not be directly attached to
the network of water and high pressure pipes. It is
mandatory to install the connecting hoses.
–
A shut-off tap must be installed between the main
water supply and the connecting hose.
Installing the high pressure connections
For installation, please follow the specifications of the
VDMA sheet 24416 "High pressure cleaners; fixed high
pressure cleaning systems; concepts, requirements, in-
stallation, testing" (the German version can be procured
from Beuth Verlag, Cologne, www.beuth.de).
–
The pressure loss in the pipe connections must lie
below 1.5 MPa.
–
The completed pipe connections must be checked
using 32 MPa.
–
The insulation of the pipes must be resistant to
temperatures until 100 °C.
Water supply
ATTENTION
Risk of damage to the plant if water supply is not of suit-
able quality.
Note: Impurities in the inlet water can damage the unit.
Kärcher recommends a water filter with a mesh width of
< 80 µm.
Quality requirements for tap water:
pH value
6,5...9,5
electrical conductivity
< 2000 µS/cm
removable materials
< 0,5 mg/l *
filterable materials (grain size be-
< 20 mg/l
low 0.025 mm)
Hydrocarbons
< 20 mg/l
Chloride
< 300 mg/l
Calcium
< 85 mg/l **
Total hardness
< 15 °dH **
Iron
< 0,5 mg/l
Manganese
< 0,05 mg/l
Copper
< 0,02 mg/l
free of bad odours
* Test volume 1litre, Settling time 30 minutes
** decalcification measures are necessary if the values
are higher
The water inlet is to be connected to the main water
supply using a water hose.
–
The water supply must have a minimum output of
6,000 l/h for HDC 60/10, 9,000 l/h for HDC 90/10,
12,000 l/h for HDC 120/10 at minimum 0.15 MPa
(HDC 60/10, HDC 90/10) or at minimum 0.2 MPa
(HDC 120/10).
–
Appliances without prepressure pump: The water
temperature must lie below 60 °C.
–
Machines with prepressure pump: The water tem-
perature must lie below 85 °C.
Electrical connection
Note: Operating procedures create short term power
sinkings. During unfavorable net conditions other devic-
es might be disturbed.
–
For connection values, see technical data and type
plate.
–
The electrical connections must be done by an
electrician according to IEC 60364-1.
–
Current-carrying parts, cables and appliances in
the working area must be installed in a defectless
state and must be protected against water sprays.
–
HDC 60/10 (H): This device complies with IEC
61000-3-12 under the condition that the short-cir-
cuit power Ssc at the connecting point between the
customer system and the public mains is greater
than or equal to 10400 (11000) kVA. It is within the
responsibility of the electrician or the user of the
unit to ensure - if necessary after consulting the
mains operating company - that the device is only
connected to a point of an Ssc value greater than
or equal to 10400 (11000) kVA.
DANGER
To avoid accidents due to electrical faults we recom-
mend the use of sockets with a line-side current-limiting
circuit breaker (max. 30 mA nominal tripping current).
11
-
EN
EU Declaration of Conformity
We hereby declare that the machine described below
complies with the relevant basic safety and health re-
quirements of the EU Directives, both in its basic design
and construction as well as in the version put into circu-
lation by us. This declaration shall cease to be valid if
the machine is modified without our prior approval.
Product:
High pressure cleaner
Type:
2.509-xxx
Relevant EU Directives
2006/42/EC (+2009/127/EC)
2009/125/EC
2011/65/EU
2014/30/EU
Applied harmonized standards
EN IEC 63000: 2018
EN 55014–1: 2017 + A11: 2020
EN 55014–2: 2015
EN 60335–1
EN 60335–2–79
EN 61000–3–2: 2014
EN 61000–3–3: 2013
EN 61000–3–12: 2011
EN 61000–6–2: 2005
EN 61000–6–4: 2007
EN 62233: 2008
Applied regulations
(EU) 2019/1781
5.957-926
The signatories act on behalf of and with of the authority
of the company management.
Chairman of the Board of Management
Director Regulatory Affairs & Certification
Documentation supervisor:
S. Reiser
Alfred Kärcher SE & Co. KG
Alfred-Kärcher-Straße 28-40
71364 Winnenden (Germany)
Tel.: +49 7195 14-0
Fax: +49 7195 14-2212
Winnenden, 2021/02/01
Warranty
The warranty terms published by our competent sales
company are applicable in each country. We will repair
potential failures of the appliance within the warranty
period free of charge, provided that such failure is
caused by faulty material or defects in fabrication.
25