11.

ERROR MESSAGES

The Power Peak Triple EQ-BID is equipped with a range of safety features to ensure that
charge and discharge processes are completed reliably. As soon as an error occurs, an
appropriate message appears on the screen, and the piezo buzzer emits a shrill warning
sound. If any of the following error messages appear, you should first eliminate the pro-
blem and then press any button to erase the message.
© robbe Modellsport
All manuals and user guides at all-guides.com
Operating instructions
Input voltage outside the permitted range (11 - 15
Volts)
Charge or discharge process started with no battery
connected: connect battery
Battery connected with reversed polarity: check con-
nections
Break in the charge / discharge circuit: check con-
nections
Short-circuit in the charge / discharge circuit: check
connections
Battery / output voltage too high: check cell count
Battery / output voltage too low: check cell count
BID chip / BID key disconnected while a process was
running: halt process, check chip connection, re-start
process
Voltage of connected cell(s) has risen above 4.3
Volts / cell
Voltage of connected cell(s) has fallen below 2.75 V
(LiPo and LiIo) or 2.0 V (LiFe) / cell
Voltage sensor lead not connected