POWER PEAK TRIPLE EQ-BID
The following voltages are available:
Cell count
1
2
3
4
5
6
ENTERING THE BATTERY CAPACITY
flashes. You can now select the battery capacity in increments of 100 mAh (PB: 500 mAh)
using the '+' or '-' button. Note that the primary purpose of the battery capacity setting for
Lithium batteries is to define the basis for the 1C charge rate for that pack, i.e. the charge
current is set automatically to the corresponding 1C charge rate for the battery. The value
Battery type
NiCd
NiMH
LiPo
LiIo
LiFe
Pb (lead-acid)
Press the '+' button to leaf through the screen display until the arrow indicates Charge
Current. Press the 'ENTER' button and the '+ / -' symbol flashes. You can now select
mum current value varies according to the cell count and / or the battery voltage (Lithium
batteries: max. 2C). The charger's integral processor limits the maximum charge current.
© robbe Modellsport
All manuals and user guides at all-guides.com
Operating instructions
Alternatively, for lead-acid batteries you can select
a battery voltage in increments of 2 V per cell using
the '+' or '-' button. Press the 'ENTER' button again
to confirm your selection.
Battery voltage
2 Volt
4 Volt
6 Volt
8 Volt
10 Volt
12 Volt
Press the '+' button to leaf through the screen
display until the arrow indicates Battery Capacity.
Press the 'ENTER' button and the '+ / -' symbol
Battery capacity
100 - 9900 mAh
100 - 9900 mAh
100 - 9900 mAh
100 - 9900 mAh
100 - 9900 mAh
0.50 mAh - 20.00 Ah
the charge current in increments of 0.1 A using the
'+' or '-' button. Press the 'ENTER' button again
to confirm your selection. The available charge
current range is 0.1 A to 5.0 A, although the maxi-
14
also provides additional safety for the
cells. Press the 'ENTER' button again
to confirm your selection. The following
capacities are available, according to
battery type.
The battery capacities are chosen to be
typical of the various battery types.
SETTING THE CHARGE CURRENT
Order No.
8541