Renson 520549 Traducción De Las Instrucciones Originales página 24

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 53
EN
in which the machine is installed;
IMPORTANT: Before
appliance, make sure that the nameplate
data are the same as those of the electrical
mains and that the socket is protected by a
differential security breaker with tripping
sensitivity below 0.03 A - 30 ms.
- If the appliance's plug is not compatible with
the socket, have the socket replaced with
another of suitable type by professionally
qualified staff.
- Never use the appliance in ambient
temperatures below 0° C if it is equipped
with a PVC (H VV-F) cable.
WARNING: Improper extension cables can be
26
dangerous. If an extension cord is used, it must
be suitable for outdoor use, and the connection
must be kept dry and clear of the ground. It is
recommended that this be done using a cable
reel that holds the plug at least 60 mm from the
ground.
WARNING: If an extension cord is used, the plug
27
and socket must be of watertight construction.
Information for supply may also be obtained
from the plug manufacturer.
230-240V
3G 2,5 mm2
max 20 m
> POSITIONING OF THE CHIMNEY FOR
INDOOR APPLICATION
(see fig. M)
• WARNING: In case of operation indoors,
adequate ventilation and gas venting must be
assured.
Sometimes a chimney is necessary to remove
the exhaustsfrom the pressure cleaner.
This problem hasn't to be faced when the ma-
chine operates outdoor, but when it's installed
indoor, the following recommendations must
be followed:
- The chimney path must be always in ascent,
straight vertical if possible, and preferably not
exceeding a 5 m lenght.
- The exit of the chimney must be sheltered
to avoid the dripping of rain and to allow the
24
connecting
400-415V
4G 2,5 mm2
max 30 m
exaust flow.
the
- The chimney section A must be 3 times the
outlet chimney of the machine B and at distan-
ce of at least 20 cm.
It must be underlined that the above recom-
mendations are extremely important to pre-
vent the condensate from back dripping into
the machine. The exausts contain sulphuric
acid, condensating at a temperature of ap-
proximately 180° C. The condensation shall
be avoid, but in any case the condensate from
chimney shall not enter the machine.
The non observance of these recommenda-
tions may lead to the damage of the machine.
CHIMNEY SECTION: 3 times the area
of chimney
Chimney pipe diameter = 150 mm
CHIMNEY SECTION FOR 2 BOILER: 6
times the area of chimney
Chimney pipe diameter = 225 mm
USAGE
> UNPACKING
(see fig. B)
Take out the upper and the lower hooks, which fix
the cardboard box to the pallet, take the cardboard
box off, put two wheels of the machine on ground
and take the pallet off.
> DESCRIPTION OF THE MACHINE
Electropump switch
Regulator burner
Detergent regulator
Pressure gauge
Burner switch
Pilot lights (OPTIONAL)
High pressure water outlet
Water inlet + filter
Gun
Lance
High pressure hose
Rubber hose fitting

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

520551

Tabla de contenido