- Activate hand spray gun until device is pressure
less.
- Lock the trigger gun.
Storing the Appliance
- Lock in the steel pipe into the holder of the ap-
pliance hood.
- Roll up high pressure hose and electrical conduit
and hang them into the respective holders.
Device with hose drum:
- Before rolling up, stretch out the high pressure
hose.
- Turn the hand crank clockwise (Direction of the
arrow).
Note: Do not twist high pressure hose and electrical
conduit.
- Store the appliance and the accessories in a dry
safe place, out of the reach of children.
- Store the appliance and the accessories in a frost-
safe room.
- This appliance must only be stored in interior ro-
oms.
CARE AND MAINTENANCE
(vedi fig. L)
IMPORTANT: Before doing any work
on the cleaner, discharge the pressure
and disconnect the electricity and water
supplies.
CHECKING THE PUMP OIL LEVEL
Check the oil level periodically. The oil must be chan-
ged for the first time after 50 working hours, with
subsequent changes every 500 hours. SAE 20/30 ,
15W-40, 20W-40 oil is recommended .
CHECKING THE WATER INTAKE FILTER
Inspect and clean the water intake filter on the in-
take union periodically. This is important to prevent
fouling which may impair operation of the pump.
CLEANING THE FUEL FILTER
Check the fuel filter periodically and replace if it has
deteriorated or is excessively dirty.
DESCALING
The descaling procedure must be carried out periodically
with specific products. The interval depends on the hard-
ness of the water. Pour one litre of product for every 15
litres of water into a drum containing at least 30 litres of
water. Disconnect the gun from the high pressure line and
place its free end in the drum, in order to form a closed cir-
cuit, and draw the solution into the machine for at least 10
minutes. The delivery end of the line should discharge into
a canvas or mesh bag so that the scale removed is not re-
turned to the circuit. Then restore the normal connection
and rinse with plenty of cold water. This operation should
be carried out by our after-sales service, since the descal-
ing product may cause wear of components. Comply with
the regulations in force when disposing of the descaling
agent.
Liquid softener tank integrated
(Optional - if included)
The descaling procedure must be carried out pe-
riodically with specific products. The interval de-
pends on the hardness of the water. This opera-
tion should be carried out by our after-sales serv-
ice, since the descaling product may cause wear
of components. Comply with the regulations in
force when disposing of the descaling agent.
- Fill the softener tank with our products (in
all cases, with non corrosive products). The
dispensing rate is set at a medium value; the
After Sales Services will be able to adapt the
setting to local conditions.
BOILER CLEANING
• WARNING: For all maintenance of the boiler, of the
high pressure pump and of the machine, it is necessary
to address to qualified personnel or to an authorized
assistance center.
The boiler cleaning must be periodically executed every
180 ÷ 200 hours of working proceeding as follows:
- Carefully remove the nozzle holder flange and
the electrodes holder (boiler head).
- Clean with compressed air the nozzle filter and
check the electrodes position.
- Remove the boiler cap, clean the deflector.
- Manually take away the interior cap.
- Unscrewing the locking nuts and take the
boiler coil out.
- Clean the coil by an iron brush.
- Suck the residuums from the boiler.
- Replace every parts doing the operations in the
EN
27