Charging Mode - GYS STARTFLASH 120.24 CNT Manual De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 50
User manual

CHARGING MODE

• General browsing:
Groupe
Group
Pb-CHARGE
Li-CHARGE
TRACTION
When accessing the mode, select the battery technology to be charged.
Charging type
Profile
(normal)
AGM
liquid
Pb-CHARGE
easy
boost
recovery+
LFP/LiFePO4
Li-ion std
Li-CHARGE
LFP cell+
Li-ion cell+
liquid
TRACTION
gel
It is possible to set the curve profile, voltage and capacity for each charging technology. To do this:
1
Scroll through the menu using the turn dial.
2
Press the turn dial to enter a parameter setting.
3
Use the turn dial to change the setting's value.
4
Press the turn dial to confirm the new parameter setting.
• Starting the charging process:
To start charging, use the turn dial to move to the arrow at
the top right of the screen and press the turn dial.
1
If the Auto-Detect feature is active, the charging process
will automatically start after the battery has been connec-
ted for five seconds.
3 Scrolling through sections (using the turn dial) provides
further information during the charging process:
1 - The stage, the progress (as a percentage) and the
2
charging time.
2 - The voltage, current and ampere hours supplied.
3 - The current charging parameter settings.
To stop charging, press the turn dial. Move the cursor to
3
, then, press the turn dial again.
Translation of the original user manual
Charging voltage
2.40 V / cell
Charges gel, MF, EFB and SLA lead-acid batteries.
Most AGM lead-acid batteries, including stop-start.
2.45 V / cell
However, some AGM batteries require a lower charging voltage (normal profile). If in
doubt, please refer to the battery's manual.
2.45 V / cell
Open liquid-type lead-acid batteries with cap.
A specific profile for lead-acid batteries that automatically adapts the charging current
according to the battery's size.
2.40 V / cell
However, using the normal, AGM or liquid charging curves is advised wherever pos-
sible for the best possible charging process.
Maximum current charging profile for lead-acid batteries. This profile can be used for
2.42 V / cell
ultra-fast charging.
2.40 - 2.50 V / cell
Specific recovery charging profile for heavily damaged, lead-acid batteries.
3.60 V / cell
Charging profile for LFP (Lithium Iron Phosphate) batteries.
Charging profile for standard manganese- or cobalt-based lithium-ion batteries (NMC,
4.20 V / cell
LCO, LMO, MCO, etc.).
A custom-designed charging profile for LFP (lithium-ion phosphate) cells with a feature
3.60 V / cell
allowing the user to select the number of cells to be charged in series.
A specific manganese- or cobalt-based, standard, lithium-ion cell charging profile
4.20 V / cell
(NMC, LCO, LMO, MCO, etc.) with as feature allowing the user to select the number
of cells to be charged in series.
2.42 V / cell
Charging profile dedicated to open lead-acid traction batteries for forklift trucks.
2.35 V / cell
Charging profile dedicated to forklift gel-type traction batteries.
Charge
Pb-CHARGE
liquid
12 V
1
2
STARTFLASH CNT
3
21

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

073616

Tabla de contenido