If the battery does not accept the pre-charge (which is often the case for overcharged batteries),
charge the battery first before attempting to start the vehicle.
If the starter requires more than 300 A, it will not be able to start.
• Stopping the start up
To stop a start-up that is already in progress, press the
3
turn dial. Move the cursor to
again.
TESTING MODE
• General browsing:
1
Select the required test using the turn dial.
2
Press the turn dial to begin the testing process.
Voltage
This mode allows the user to display the voltage at the charging clamps' terminals and, there-
fore, use a STARTFLASH device as a voltmeter to measure the battery's voltage.
Start-up TEST
The purpose of this mode is to evaluate the vehicle's starting system (starter and battery) when the engine is switched on. This test
must be carried out with the battery connected to the vehicle.
1 Use the turn dial to select the vehicle's battery voltage rating.
2 Press the turn dial to confirm.
3 Connect the clamps to the vehicle's battery.
4 Start the engine by turning the ignition key.
The charger automatically detects the engine's start-up attempt and runs a calculation
5
algorithm to determine the start-up system's status.
Test result: The charger indicates the battery voltage minimum value detected during
6
the engine's starting phase, as well as a gauge that indicates the state of the starting
system.