User manual
Warnings:
It is advisable to reduce the vehicle's power consumption to a minimum (switching off the lights, turning off the ignition and closing
the doors, etc.) when charging a vehicle; this is in order to avoid disrupting the charging process.
Check the electrolyte level for open batteries. Top up levels before charging, if necessary.
• Charging stages
Charging curve LEAD:
1
2
U
I
Analyse
Récupération
0%
Stage 1: Analysis
Battery-status analysis (charge level,
reverse polarity, wrong battery connected
etc.)
Stage 2: Recovery
Algorithm for recovering damaged ele-
ments following a deep discharge.
Stage 3: Testing
Sulphated battery test.
Stage 4: Desulphation
Battery desulphation algorithm.
Stage 5: Charging
Fast charging at maximum current to
achieve an 80% charge level.
22
Translation of the original user manual
3
4
Test
Désulfatation
10%
20%
5
6
7
Charge
Absorption
Test
Absorption
80%
Stage 6: Absorption
Constant voltage charging to bring the
charge level up to 100%.
Stage 7: Absorption Test
Charge retention test.
Stage 8: Refresh (only for the liquid-bat-
tery profile)
The charger supplies additional power to
create a gas that mixes the electrolytes
and reconditions the battery cells. The
battery may lose a little water during this
phase.
Stage 9: Charge holding
Maintaining the battery's charge level at
its maximum level.
STARTFLASH CNT
8
9
Refresh
Maintien de
charge
(si option active)
98%
100%