GYS STARTFLASH 120.24 CNT Manual De Uso página 33

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 50
User manual
10
Err11: Time_Out
11
Err12: Q>___Ah
12
Err13: U<__V
13
Err14: Bat_UVP
14
Err15: U<__V
15
Err16: Bat_NOK
16
Err17: Recov_NOK
17
Err18: U>0V
18
Err19: Cable_NOK
19
Err20: U<__V
20
Err21: U<__V or Err22: U<__V
21
?
22
?
23
24
Err27: Cable_NOK
25
Err28: COM_NOK
26
Err29:Time_Out
GUARANTEE
The warranty covers all defects or manufacturing faults for two years from the date of purchase (parts and labour).
The warranty does not cover:
• any other damage caused by transporting the device
• the machin'es normal wear and tear (e.g . cables and clamps, etc.)
• incidents due to misuse (misfeeding, dropping or dismantling the machine)
• environmentally-related breakdowns (pollution, rust or dust, etc.)
In the event of a breakdown, return the device to your distributor, along with:
- dated proof of purchase (receipt or invoice)
- a note explaining the breakdown
Translation of the original user manual
Setting the time limit
Abnormally long charging process
Setting the overload protection
Unusually low battery voltage when
checking the charging process
Unusually low battery voltage during
UVP Wake up
Battery too low
HS Battery
Battery recovery failed
Voltage passing through the clamps
during cable calibration
Cable calibration failed
Setting the unusual under-voltage
protection
Unusually low battery voltage when
holding a charge
USB key not detected
No configuration file (.sfc) is present
on the key
Corrupted file
Multi-charger mode:
Failure to parallel the charging cables
Multi-charger mode:
Communication failure between
chargers
The start-up time has passed.
Consumers on the battery are disrupting the charging process
Battery to be replaced
Consumers on the battery are disrupting the charging process
Battery to be replaced
Battery to be replaced
Short-circuit detected, check assembly
Battery to be replaced
Check that the selected mode is compatible with the battery's
voltage level (e.g . 24 V battery on a 12 V charging mode)
Battery to be replaced
Battery to be replaced
Battery to be replaced
Check the set-up
Charging cables to be replaced
Poor connection, check the assembly
Short-circuit detected, check assembly
Battery to be replaced
Consumer detected on the battery
Check that the USB key is properly connected to the charger
Check that your files are saved on the USB stick. Do not save
them in a folder or sub-folder.
The file you want to download is corrupted. Delete and reinstall
the file on the USB key.
Charging cables to be replaced.
Poor connection, check the assembly (PHM).
To switch back to operating with a single charger,
select «OFF» when settings the multi-charger feature.
No communication, check SHM assembly and SLAVE X charger
configuration.
To switch back to operating with a single charger, select OFF
when choosing the multi-charger feature.
Re-start the start-up process. If this attempt fails again, the
battery is too discharged. Charge the battery using the charging
mode.
STARTFLASH CNT
33

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

073616

Tabla de contenido