Lithium charging curve LFP:
1
2
U
I
Analyse
UVP Wake up
Récupération
0%
Stage 1: Analysis
Battery-status analysis (charge level,
reverse polarity, wrong battery connected
etc.)
Stage 2: UVP Wake up
Reactivates batteries in UVP protection
(Under Voltage Protection)
Stage 3: Recovery
Recovery algorithm following a deep
discharge.
Stage 4: Charging
Fast charging at maximum current to
achieve an 90% charge level.
Stage 5: Absorption
Constant voltage charging to bring the
charge level up to 95%.
POWER SUPPLY MODE | BSU
• General browsing:
1
Scroll through the menu using the turn dial.
2
Press the turn dial to enter a parameter setting.
3
Use the turn dial to change the setting's value.
4
Press the turn dial to confirm the new parameter setting.
POWER SUPPLY MODES
SHOWROOM
DIAG+
CHANGE BAT.
POWER SUPPLY
Li-SUPPLY/LFP
Li-SUPPLY/Li-ion
Translation of the original user manual
3
4
Charge
2%
85%
Ensures that the battery's state of charge is maintained and that the demonstration vehicle's energy requirements
are met when using electrical accessories.
Provides the energy required during the vehicle's diagnostic phase.
Allows the vehicle's power supply to be maintained when the battery is replaced; this preserves the vehicle's ECU
memory.
Warning: reversing the polarity during use can damage the charger and the vehicle's electronics.
Allows the charger to be used as a high-power, adjustable and stabilised power supply. The voltage to be regulated
and the current limits are fully adjustable.
Warning: reversing the polarity during use can damage the charger and the vehicle's electronics.
This mode is designed to supply LFP (lithium-ion phosphate) cells with additional features, such as selecting the
number of cells in series and adjusting the voltage and current to be delivered.
This mode is aimed at supplying manganese- or cobalt-based, standard, lithium-ion cells (NMC, LCO, LMO, MCO,
etc.); it also boasts a range of special features, including the possibility of selecting the number of cells in series
and adjusting the voltage and current to be delivered.
5
6
7
Equalising Battery System
Absorption
Test
Complément
95%
STARTFLASH CNT
8
9
Egalisation /
Maintien de charge
équilibrage
99%
100%
Stage 6: Testing
Charge retention test.
Stage 7: Additional information
Reduced current charging to achieve a
100% charge level.
Stage 8: Equalisation / balancing
Balancing the battery cells
Stage 9: Charge holding
Maintaining the battery's charge level at
its maximum level.
BSU
1 2 V
13.5 V