Restores either:
- the previous saved configuration: ʺ Previous Conf ʺ .
- the factory settings: ʺ Total reset ʺ(Reset total).
Portability
The appliance's USB features can be accessed from the sub-menus section; further details about this section are provided below.
Cable calibration
Procedure for calibrating the device's charging cables, so that the charger optimally compensates for the voltage loss caused by the
cables. It is strongly recommended that this procedure be carried out at least once a year as well as whenever the charging cables
are replaced.
Calibration procedure:
1 Go to the cable cali bration menu.
2 Short-circuit the clamps.
3 Press
to start the cable calibration procedure.
: The calibration was performed correctly.
4
Err19: Cable_NOK : A problem occurred while calibrating the cables.
Check that the cables are in good condition and correctly short-circuited and, then, repeat the operation.
28
Translation of the original user manual
Traceability
Make sure that the jaws' metal parts to which the cables are attached are in good
contact with each other.
OK
NOK
STARTFLASH CNT
NOK