Setup regulati-
ons
Danger from machines falling or toppling over.
This can result in serious injury and damage to property.
The device is tested to IP40 protection, meaning:
-
-
The device must be set up and operated in dry, closed areas that comply with de-
gree of protection IP40.
-
Dust:
-
-
54
Risk of explosion! Oxyhydrogen is generated in the battery during char-
ging.
Battery acid is corrosive and must be kept away from eyes, skin and
clothes.
Ensure an adequate supply of fresh air during charging. Maintain a di-
stance of at least 0.5 m (19.69 in.) between the battery and charger
during the charging procedure.
Do not dispose of used devices with domestic waste. Dispose of them
according to the safety rules.
WARNING!
Place the device on a solid, level surface so that it remains stable or set up
on a level surface according to the "Installation" section.
The "Installation" section is in the "Control elements and connections" chap-
ter.
Protection against penetration by solid foreign bodies with diameters excee-
ding 1.0 mm (0.04 in.)
No protection against water
Avoid direct wetting
Ensure that metallic dust is not sucked into the system by the fan,
e.g. during grinding work