Danger following ignition of oxyhydrogen caused by sparks resulting from the
charging leads being disconnected too soon.
This can result in serious injury and damage to property.
8
Interrupting the
NOTE!
charging process
Danger from disconnecting or unplugging the charging lead during charging.
This can result in damage to connection sockets and connecting plugs.
Restarting char-
2
ging
WARNING!
Before disconnecting the charging leads, press the Stop/Start key to finish
charging.
To end the charging process:
7
-
Press the Stop/Start key
Disconnect the charger
-
Disconnect the black charging lead from the negative pole (-) of the bat-
tery
-
Disconnect the red charging lead from the positive pole (+) on the batte-
ry
Do not disconnect or unplug charging leads while charging.
Press the Stop/Start key while charging
1
-
Press the Stop/Start button to continue charging
The charging process is interrupted