Reactivating Batteries - Fronius Acctiva Smart 25 A Manual De Instrucciones

Ocultar thumbs Ver también para Acctiva Smart 25 A:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 173
Danger from battery acid.
This can result in personal injury.
Refresh mode may be used on the following batteries:
-
-
Reactivating bat-
NOTE!
teries
Danger of deep-discharged batteries freezing at 0 °C (32 °F).
A frozen battery can become damaged.
1
CAUTION!
Wear eye protection and suitable protective clothing when handling battery
acid.
Rinse any acid splashes immediately and thoroughly with clean water.
Seek medical attention if necessary.
Do not inhale any of the gases and vapours released under any circumstan-
ces.
Wet batteries:
sealed batteries with a liquid electrolyte (identifiable on the vent plugs)
After reactivating, check the acid level and top up with distilled water if ne-
cessary.
Absorbent Glass Mat (AGM) batteries:
sealed batteries (VRLA) with immobilised electrolyte (sealant) and mainten-
ance-free wet batteries (MF)
Before starting refresh charging, ensure that the acid in the battery to be re-
freshed is not frozen.
Plug in charger mains plug
Select Refresh mode using the up/down keys.
2
Use the Menu key to select the "Ah" or "Battery type"
3
setting.
Use the Up/Down keys to enter the required value (e.g.
4
100 Ah or "Wet" battery type).