Install Adapter Set As 2/C-100 - Bosch rexroth LU 2/P Instrucciones De Montaje

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 171
26/42
Assembly
Please note:
• The elbow fi tting is
included in the scope of
delivery of the dosing
valve set.
1.
Install the elbow
fi tting (C) in the
lubrication pin (A).
2.
Insert the lubrication
pin (A) in the correct
position in the drill bore
of the drive head.
3.
Secure the lubrication
pin (A) with the lock
washer (B).
4.
Install the lubrication
line.
Please note:
Bosch Rexroth AG, MIT: LU 2/P-24V-3L, 3 842 557 976/2020-08
8.5.4
Install adapter set AS 2/C-100, -250
Fig. 8:
Install adapter set AS 2/C-100, -250
• Only use 2 equal lubrication pins per section (do not mix adapter sets). Diff erent
lubrication pins cause unequal distribution through an uneven fl ow resistance.
• Fill the lubrication line before start-up, e.g. by repeatedly pressing the lubricating
device (pressing the manual cycle button on the lubricating unit) until lubrication
comes out of the lubrication pin.
A
B
C
SW13
M =4 Nm
D
577 976-06

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

3 842 562 921

Tabla de contenido