BTL PA0400- _ _ _ _ -C15A _ _ _ _ -000S15
Magnetostrictive Linear Position Sensor – Profile Style
6
Commissioning and operation (continued)
6.2

Operation

Characteristic
BTL
curve
Rising
...-C15AA...
...-C15AE...
Falling
...-C15A1...
...-C15A5...
Tab. 6-1:
Value table for factory default
6.3

Operating notes

Some settings can be modified (see Configuration with
the Balluff Engineering Tool (BET) on page 14).
Regularly check function of the BTL and all associated
components.
Take the BTL out of operation whenever there is a
malfunction.
Secure the system against unauthorized use.
Check fasteners and retighten if needed.
6.4

Maintenance

The product is maintenance-free.
www.balluff.com
Null point
Unit
Minimum
Null value
value
V
−0.4
mA
3.6
V
10.4
mA
20.4
End value
Maximum
0
10.0
4.0
20.0
10.0
0
20.0
4.0
End point
Error value
value
10.4
10.5
20.4
1.8
−0.4
10.5
3.6
1.8
english