Technical Data; Ambient Conditions; Detection Range/Measuring Range; Electrical Data - Balluff BTL PA0400 Serie Manual De Instrucciones

Ocultar thumbs Ver también para BTL PA0400 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 69
BTL PA0400- _ _ _ _ -B15A_010-000S92
Magnetostrictive Linear Position Sensor – Profile Style
8

Technical data

The values are typical for the
BTL PA0400- _ _ _ _ -B15A_010-000S92 at 24 V DC, room
temperature and a measurement length of 500 mm
together with magnet BTL6-A-3800-2 or BTL6-A-3801-2.
The product is immediately ready for operation, full
accuracy is achieved after the warm-up phase.
Further data can be found at www.balluff.com
on the product page.
8.1

Ambient conditions

Ambient temperature
Storage temperature
Relative humidity
Typ. temperature coefficient
1)
Shock rating as per
EN 60068-2-27
2), 3)
Continuous shock per
EN 60068-2-27
2), 3)
Vibration per EN 60068-2-6
2), 3)
Protection per IEC 60529 (when
threaded together)
8.2

Detection range/Measuring range

Measuring length
Analog resolution
...-B15AA/-B15A1...
...-B15AE/-B15A5...
Repeat accuracy
Measuring length ≤ 500 mm
Measuring length > 500 mm
Length-dependent measuring
frequency
Measuring length ≤ 1270 mm
Measuring length > 1270 to
≤ 2650 mm
Measuring length > 2650 mm
Non-linearity
with measuring length ≤ 500 mm
with measuring length > 500 to
≤ 4000 mm
Detectable speed
www.balluff.com
8.3
Operating voltage U
Current draw (at 24 V DC)
Power consumption
Overvoltage protection
Voltage-proof up to (GND –
Housing)
−25...+75 °C
...-B15AA/B15A1...
−40...+85 °C
≤ 90%, non-
...-B15AE/B15A5...
condensing
≤ 30 ppm/K
100 g/6 ms
8.4
Short circuit protection
50 g/2 ms
Reverse polarity protected
12 g,
10...2000 Hz
8.5
IP67
...-B15AA...
...-B15A1...
25...4000 mm
...-B15AE...
183 μV / ≥ 4 μm
...-B15A5...
351 nA / ≥ 4 μm
≤ ±10 µm
Measuring length 500 mm, magnet in the middle of the measuring range
1)
≤ ±0.002% FS
2)
Individual specifications as per Balluff standard
Resonant frequencies excluded
3)
4)
A prerequisite is that no current can flow between GND and 0 V in the
1000 Hz
event of polarity reversal.
500 Hz
250 Hz
±200 μm
±0.04% FS
≤ 10 m/s

Electrical data

b
...-B15AA/B15A1...
...-B15AE/B15A5...
...-B15AA/B15A1...
...-B15AE/B15A5...
Output current
Load resistance R
Lc

Electrical Connection

4)

Output / Interface

Analog, voltage
Analog, voltage
Analog, current
Analog, current
10...30 V DC
≤ 60 mA
≤ 80 mA
≤ 1.5 W
≤ 2.0 W
U
up to 36 V DC
b
500 V DC
≤ 5 mA
≤ 500 ohm
to GND and 30 V DC
U
up to 30 V DC
b
0...10 V
10...0 V
4...20 mA
20...4 mA
english
13

Publicidad

Tabla de contenido
loading

Tabla de contenido