Nilfisk Advance SC3000 Instrucciones De Uso página 20

Ocultar thumbs Ver también para Advance SC3000:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ENGLISH
EcoFlex system disabling procedure
In order to temporarily disable the system, lift the EcoFlex lever (D, Fig. 3) and keep it lifted for 2 seconds.
After this procedure, (LED (D) off), the detergent concentration level is the one which has been set.
To enable the system, lift the EcoFlex lever (D) again.
In order to permanently disable the EcoFlex system, proceed as follows:
1.
Turn off the machine by turning the ignition key (58) to "0".
2.
Lift the lever (D), then turn the ignition key (58) to "I".
3.
Release the lever (D) at least 8 seconds after turning on the machine.
After this procedure, the EcoFlex lever cannot be operated again (LED (E) off) and the detergent concentration level is the one
which has been set.
In order to re-enable the system, repeat the steps 1 to 3.
NOTE
The permanent disabling of the EcoFlex system is stored into memory even after the machine is turned off.
D
18
INSTRUCTIONS FOR USE
E
LEVEL
DISPLAY
1
2
3
4
5
6
SC3000 26 D - 9098827000
RATIO
%
oz./gal
1:400
.25
1:250
0.4
½
1:125
0.8
1
1:100
1.0
1⅓
1:50
2.0
1:33
3.0
4
Figure 3
revised 03/2018
C
B
A
P100365A
10/2010

Publicidad

Tabla de contenido
loading

Tabla de contenido