Commissioning; Tips And Advice On Installation - SOMFY Sonesse 40 RS485 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 34
EN

2.3.Commissioning

The drive has 2 blinds profile inside:
▪ Roller mode (to control all blinds except Venetians).
▪ Venetian mode.
Two tools are available to set the drive.
▪ RS485 SETTING TOOL: Connect the RS485 SETTING TOOL to the drive
switch on and follow the instruction on the RS485 SETTING TOOL.
NOTICE
• Venetian mode allows to manage the tilt and the lift position. It is not
possible to set the drive-in venetian mode through the RS485 SETTING
TOOL.
• When setting end limits, take care that the load bar remains free at upper end
Limit.
▪ SDN Config Tool: Somfy Digital Network Configuration Tool.
NOTICE
The SDN Config Tool is available for download at https://www.somfy.com/projects/downloads
NOTICE
The different versions of which are available in the current Somfy catalogue.

2.4.Tips and advice on installation

2.4.1.Questions about the drive?
Observations
The motorised
"Power" or "datas" wiring are incorrect.
product does not
The drive is in thermal protection mode. LED
work.
Red = ON then lights OFF.
An incorrect Data cable has been used
End-limits are not properly adjusted.
The motorised
The wheel and the crown are not adapted to the
product is noisy.
used tube.
The mechanical plays between drive, accessories,
tube and end of tube are too high.
The wheel is not properly fixed to the tube.
The equipment is constrained between the
brackets.
The length of the notch is not adapted to the drive
hook or to the used crown.
Debris, screws or other are in the tube.
The temperature of the environment is not in
conformity with the operating temperature.
The motorised
The end limits of the motorised product slip.
product stops too
The motorised product does not fall within the
soon or too late.
recommended weight limits.
6
Possible causes
Solutions
Check the wiring and modify it if necessary.
Wait for the drive to cool down to restart the
drive.
Do not touch the drive: risk of burns.
Check the Data cable.
Adjust the end-limits.
Change the wheel and the crown.
The mechanical plays between drive, accessories,
tube and end of tube must be decreased to the
minimum.
Fix the wheel properly to the tube.
Decrease the constraint between the brackets.
Adapt the length of the notch to the drive hook or
to the used crown.
Empty the tube.
Change the environment temperature.
Re-set the end limits.
Check the compatibility of the motorised product.
Consult a Somfy contact or visit www.somfy.com.
©
Copyright
2021 SOMFY ACTIVITES SA. All rights reserved.
Sonesse 40 RS485

Publicidad

Tabla de contenido
loading