Technical Data; General Data And Protection Devices 10.0-3 208-240 / 24.0-3 208; Technical Data Fronius Symo Advanced 10.0-3 208-240 / 12.0-3 208 - Fronius Symo Advanced 10.0-3 208-240 Manual De Instrucciones

Ocultar thumbs Ver también para Symo Advanced 10.0-3 208-240:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Technical data

General data and
General data
protection
Cooling
devices 10.0-3
208-240 / 24.0-3
Protection class
208-240
Dimensions h x w x d
Permitted ambient temperature
Permitted storage temperature
Permissible humidity
Noise emission
Protection devices
Reverse polarity protection
Stand-alone operation protec-
tion
Arc Fault Circuit Interrupter/
interruption
Photovoltaic insulation monitor-
ing
High temperature
Technical data
Fronius Symo
Fronius Symo Advanced
Advanced 10.0-3
208-240 / 12.0-3
Input data
208-240
MPP voltage range
Input voltage range (at 1000 W/m²/14 °F in
an open circuit)
Max. input current (MPP1/MPP2)
(MPP1 + MPP2)
Max. short circuit current of solar modules
(I
SC PV
Max. inverter backfeed current to the array
1)
Output data
Nominal output power (P
Max. output power (+104 °F)
) (MPP1/MPP2)
)
nom
Controlled forced-air ventilation
NEMA 4X
28.5 x 20.1 x 8.9 in.
725 x 510 x 225 mm
-40 °F to +140 °F (-40 °C to +60 °C)
-40 °F to +158 °F (-40 °C to +70 °C)
0 - 100%
65 dB(A) (ref. 1pW)
Integrated
Integrated
Integrated
Integrated
Operating point shift/active cooling
10.0-3 208-24
0
300 - 500 V DC
200 - 600 V DC
25.0/16.5 A
41.5 A
37.5 / 24.8 A
0.0 A
9995 W
9995 W
12.0-3 208-24
0
2)
11,995 W
11,995 W
51