Fronius Symo Advanced
Max. output power (+140 °F)
Rated apparent power
Phases
Nominal grid voltage
Operating range AC voltage
Adjustment range for grid voltage
Max. continuous output current
at V
Recommended min. AC over-
current protection
Max. output fault current per duration
Nominal frequency
Total harmonic distortion
Power factor (cos phi)
General data
Maximum efficiency
CEC efficiency
Weight (full/lite version)
1)
2)
3)
Technical data
Fronius Symo Advanced
Symo Advanced
15.0-3 480
Input data
MPP voltage range
Input voltage range (at 1000 W/m²/14 °F in
an open circuit)
52
nom
The maximum current from the inverter to the solar modules if an error
occurs on the inverter.
Assured by the electrical design of the inverter
ind. = inductive cap. = capacitive
10.0-3 208-24
0
at 208 V
8000 W
at 220 V
8600 W
at 240 V
8600 W
9995 VA
at 208 V
at 220 V
at 240 V
60 - 152 V/104 - 288 V
at 208 V
27.7 A
at 220 V
26.2 A
at 240 V
24.0 A
at 208 V
35.0 A
at 220 V
35.0 A
at 240 V
30.0 A
43.1 A / 158.4 ms
< 1.5%
0 - 1 ind./cap.
at 208 V
96.50%
at 240 V
96.50%
90.4/89.5 lbs. (41.0/40.6 kg)
350 - 800 V DC
200 - 1000 V DC
12.0-3 208-24
0
8000 W
8600 W
8600 W
11,995 VA
3 ~ NPE
120/208 V
127/220 V
120/240 V
-12 to +10%
33.3 A
31.5 A
28.9 A
45.0 A
40.0 A
40.0 A
50/60 Hz
< 1.75%
3)
97.00%
96.50%
96.50%
15.0-3 480