Electrical Installation - SICK RSB Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
OPERATING INSTRUCTIONS
6

Electrical installation

en
32
O P E R A T I N G I N S T R U C T I O N S | RSB - Roller Sensor Bar
Operation in standard I/O mode:
The sensors must be connected in a voltage-free state. The following information must
be observed, depending on the connection type:
Male connector connection: Pin assignment
Cable: Wire color
Only apply voltage and switch on the voltage supply once all electrical connections have
been established.
Operation in IO-Link mode: Connect the device to a suitable IO-Link master. Integrate
into the master or into the controller using IODD / function block. The green LED
flashes on the sensor. IODD and function block are available to download from
www.sick.com
under the part number.
Explanation of the connection terminology used in the following tables:
BN = Brown
WH = White
BU = Blue
BK = Black
n. c. = Not connected
Q1 = Digital output 1
Q2 = Digital output 2
L+ = Supply voltage (U
)
V
M = Ground
L.ON = Light switching
D.ON = Dark switching
DC:
Standard version 10 ... 30 V DC ,
IO-Link version 18 ... 30 V
DC,see "Technical data", page 37
Table 3: Connection types
Flying leads
M8, 3 pin
M8, 4 pin
3
1
3
4
4
M12, 4 pin
1
2
1
2
3
4
8027085/2022-05-31 | SICK
Subject to change without notice

Publicidad

Tabla de contenido
loading

Tabla de contenido