Descargar Imprimir esta página

Balluff BIR 01-K15AL-000S92 Serie Manual De Instrucciones página 36

Ocultar thumbs Ver también para BIR 01-K15AL-000S92 Serie:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 101
BIR 01- _ _ _ _ -K15AL _-000S92
Inductive Rapid Positioning System
4
Product description (continued)
Namur Standard
Name
Device Discovery
Short Circuit Pin 2 / Pin 4
Measurement Error
Failure
Teach-in
Maintenance Required
Overload
Out of Specification
Communication
Ready Diagnosis On
Ready Diagnosis Off
Tab. 4-2:
Meaning of the LED states – Namur Standard
4.4
Part label
BIRXXXXX
BIR XX-XXXX-XXXXXX-XXXXXX
CCOOOOOOOOOSSSSS
Order code
1)
Type
2)
Serial number
3)
Fig. 4-3:
Part label (section, example)
10
english
Signal
Meaning
Blue flashing, 3 Hz
The Device Discovery can be activated via a system command to
find the device again.
Red flashing, 3 Hz
Short circuit at pin 2 or pin 4
Red flashing, 1 Hz
This signal occurs if a measurement error occurs. The measurement
value is unknown due to an error or outside of the measuring range.
Red, static
General error
Red, static
The device is currently in teach-in mode
Blue, static
Maintenance must be performed.
Orange flashing, 3 Hz
Overload on pin 2 / pin 4 has been detected.
Yellow flashing, 3 Hz
The device is operated outside of specifications. A reliable
measurement signal can no longer be ensured.
Green, alternating with
IO-Link communication is active. The device is ready.
LED off in a ratio of
10:1, 1 period
Green, static
The device is ready. Diagnosis functions are on.
Static white
The device is ready. Diagnosis functions are switched off.
max. 10 - 30 V DC
<150 mA
1)
2)
3)
Balluff GmbH
Schurwaldstr. 9
DE-73765
Neuhausen a.d.F.
+49 7158 173-0
www.balluff.com
Proc. Cont. Eq.
E227256
Type 1

Publicidad

loading