BIR 01- _ _ _ _ -K15AL _-000S92
Inductive Rapid Positioning System
6
Startup and operation
6.1
Startup
Uncontrolled system movement
When starting up, if the BIR is part of a closed loop
system whose parameters have not yet been set, the
system may perform uncontrolled movements. This
could result in personal injury and equipment damage.
► Persons must keep away from the system's
hazardous zones.
► Startup must be performed only by trained technical
personnel.
► Observe the safety instructions of the equipment or
system manufacturer.
1. Check connections for tightness and correct polarity.
Replace damaged connections.
2. Turn on the system.
3. Check measured values and adjustable parameters
and readjust the BIR if necessary. Check spacing over
the entire measuring range.
Check for the correct values, especially after
replacing the BIR or after repair by the
manufacturer.