BIR 01- _ _ _ _ -K15AL _-000S92
Inductive Rapid Positioning System
6
Startup and operation (continued)
6.2
Operation
BIR type
Variant
...-K15ALA-
0...+10 V
...-K15ALE-
4...20 mA
Tab. 6-1:
Value table for factory default
6.3
Operating notes
Some settings can be modified (see Configuration with
the Balluff Engineering Tool (BET) on page 16).
Regularly check function of the BIR and all associated
components.
Take the BIR out of operation whenever there is a
malfunction.
Secure the system against unauthorized use.
Check fasteners and retighten if needed.
6.4
Maintenance
The product is maintenance-free.
www.balluff.com
Null point
Characteristic
Minimum
curve
value
−0.4 V
Rising
3.6 mA
Null value
End value
0 V
+10 V
+4 mA
+20 mA
End point
Maximum
Error value
value
+10.4 V
+11 V
+20.4 mA
+1.8 mA