5.3.1.1 Change Dose Times
Pressing the item "Change Dose Times"
from the "Technical Settings" menu ac-
cess the pages for setting of the grinding
time for the single dose and the double
dose.
Note: to move from the grinding time set-
ting page for the single dose to the grind-
ing time setting page for the double dose
(and vice-versa) simply scroll horizontal-
ly the displayed screen.
Use the function keys
crease or decrease the delivery times.
Saving of the modified parameters takes
place automatically when the page is ex-
ited.
5.3.1.2 Dose Times Visibility
When "Grinding time visibility" in the
"Technical settings" menu is enabled (
), the times set for the different dos-
es are displayed on the HOME screen.
During dispensing, the icon of the key
relating to the selected dose begins to
flash and to gradually turn red until it is
completely filled, thus displaying the pro-
gress of the grinding phase in progress.
In the case of manual grinding, the time
is displayed to increase up to a maximum
delivery of 25 seconds, after which the
grinding is automatically stopped.
If the "Dose Times Visibility" option is dis-
abled (
), the dose dispensing times
are not displayed on the HOME screen.