OPERATING MODE
1.
Turn the rotary CH knob (6) or use the UP/DN buttons (13) on the microphone
to select the
menu.
2.
Briefly press the EMG key (5) to confirm. The operating mode flashes (I d or
DF).
3.
Turn the rotary CH knob (6) or use the UP/DN buttons (13) on the microphone
to select the desired operating mode.
STORING A CTCSS/DCS CODE
Depending on the operating mode used, the procedure differs:
Identical mode I d
4.
A short press on the EMG key (5) makes the genre blink ("CTCSS", "DCS" or
"OFF" no genre).
5.
Turn the rotary CH knob (6) or use the UP/DN buttons (13) on the microphone
to select the genre or...
6.
Press the EMG key (5) to confirm the genre. The code value flashes (unless
OFF selected).
7.
Turn the rotary CH knob (6) or use the UP/DN buttons (13) on the microphone
to select the code (from 01 to 38 for CTCSS and 001 to 104 for DCS).
Different Mode DF
4.
A short press on the MENU key (4) makes the type RX blink.
5.
Turn the rotary CH knob (6) or use the UP/DN buttons (13) on the microphone
to select the RX or TX type.
6.
A short press on the EMG key (5) validates the choice of type. The genre
value flashes ("CTCSS", "DCS" or "OFF" no code).
7.
Turn the rotary CH knob (6) or use the UP/DN buttons (13) on the microphone
to select the genre or...
8.
Press the EMG key (5) to confirm the genre. The code value flashes (unless
OFF has been selected).
9.
Turn the rotary CH knob (6) or use the UP/DN buttons (13) on the microphone
to select the code (01 to 38 for CTCSS, 001 to 104 for DCS).
10. Press the EMG key (5) to confirm the selected code. The unit return to point
5, for set the second type.
11. If you don't need to set the second type, long press the EMG key (5) to
validate and exit the MENU.
12. If no key is pressed, the device exits the MENU after 10 seconds without
saving the changes.
The default mode is I d (Identical). The default genre is OFF.
14) RESET
This function allows to Erase the scan skip memory or restore all factory
settings.
Press F key (8).
is displayed.
Long press F key (8) to enter the MENU.
1.
Turn the rotary CH knob (4) or use UP/DN buttons (13) on the microphone
to select the
menu.
2.
Press EMG key (6) to validate. The current value blinks on the display.
3.
Turn the rotary CH knob (4) or use the UP/DN buttons (13) on the microphone
to select SC or AL.
4.
Short press the EMG key (6) to validate. a) Return to the point 1 to set an-
other menu or b) Short press the F key (8) to validate and exit the MENU.
disappears from the display.
5.
If no key is pressed, the unit exits MENU after 10 seconds.
from the display.
SC erase all the channels stored on the SCAN SKIP memory. They are now
enabled to be scanned (see the § SKIP page 9).
AL restore all the factory parameters.
E) TECHNICAL CHARACTERISTICS
1) GENERAL
- Channels
- Modulation modes
- Frequency ranges
- Weather channels
- Antenna impedance
- Power supply
- Dimensions (L x D x H)
- Weight
- Accessories supplied
2)
TRANSMISSION
- Frequency allowance
- Carrier power
- Transmission interference
- Audio response
- Emitted power in the adj. channel : inferior to 20 µW
- Microphone sensitivity
15
disappears
: 40
: AM / FM
: from 26.965 MHz to 27.405 MHz
: 162,400 MHz to 162,550 MHz
: 50 ohms
: 13.8 V / 27.6 V
: 4.92 x 6.49 x 1.77 inches
125 x 165 x 45 mm
: 1.65 lbs / 0.75 kg
: 1 microphone electret UP/DOWN with
support, mounting cradle, screws and
fused power cord.
: +/- 200 Hz
: 4 W AM / 4 W FM
: inferior to 4 nW (- 54 dBm)
: 300 Hz to 3 KHz in AM/FM
: 3.0 mV