Descargar Imprimir esta página

Nilfisk Advance SW4000 Instrucciones De Uso página 8

Ocultar thumbs Ver también para Advance SW4000:

Publicidad

Idiomas disponibles

Idiomas disponibles

MACHINE DESCRIPTION
MACHINE STRUCTURE
ENGLISH
Guide lines to bacteria control and other dangers coming from the presence of microbes in the DustGuard™
system (optional).
6
WARNING!
Do not store the machine outdoors or near sources of heat.
If the machine is not used for more than one week, empty the tank completely, and let it dry before storing
it.
If the tank cannot be cleaned regularly, consider using a biocide that can kill or exert a controlling effect on
to the relevant instructions and cautions, to avoid that the personnel gets affected by dangerous chemical
substances.
If chemical products have to be used in the water tank, it is mandatory to apply the relevant information and
caution labels of the product.
1.
Steering wheel
2.
Control panel (see the following paragraph)
3.
Driver's seat with safety microswitch
4.
Seat position adjusting lever
5.
Drive pedal
6.
Service brake pedal
7.
Parking brake lever: press both the service brake (6) and
the lever (7) to switch from the service brake to the parking
brake
8.
Front skirt lifting pedal
9.
Hopper release and discharge lever
10. Rear hood with vacuum system
11. Hopper (empty it when it is full)
12. Right door (to be opened for performing maintenance
procedures only)
13. Left door (for main broom removal)
14. Right side broom
15. Left side broom
16. Side broom guards
To prevent the operators and other people from developing infections caused by microbes and Legionella that
may flourish in the dust guard system, take the following precautions:
If possible, fill the tank with cold water (< 20 °C).
DO NOT use stagnant water to fill the tank.
DO NOT use recycled water, undrinkable water or water that has been in contact with the soil.
Adjust and turn the nozzles towards the floor only, from preventing possible inhaling.
Do not over-fill the tank. Fill the tank sufficiently so that it can be emptied by using the system.
Empty the tank every 10 hours or once a week, according to the use.
Legionella bacteria. Biocide must be chosen according to the local regulations and must be used according
INSTRUCTIONS FOR USE
SW4000 - 1464818000
17. Main broom
18. Battery compartment hood
19. Can holder
20. Rear wheels
21. Front driving and steering wheel
22. Dust filter container
23. Panel filter with filter-shaker
24. Front column / Dust guard system water tank (optional)
25. Dust guard system water filler neck plug (optional)
26. Dust guard system nozzles (optional)
27. Working lights (optional)
28. Flashing light (always on when the ignition key is turned to
"I") (optional)
29. Safety belt (optional)
30. Serial number plate/technical data
31. Anchoring slots for transport (not for lifting)
32. Hopper manual returning handle