During HEAT MODE test running, the default target outlet
water temperature is 35°C. The IBH (internal backup heater)
will turn on after the compressor runs for 10 min. After the
IBH runs for 3 minutes, the IBH will turn off, the heat pump
will operate until the water temperature increase to a certain
value or the next command is received.
When the DHW MODE RUNNING is selected, the following
page will be displayed:
During DHW MODE test running, the default target
temperature of the domestic water is 55°C. The TBH (tank
boost heater) will turn on after the compressor runs for
10min. The TBH will turn off 3 minutes later, the heat pump
will operate until the water temperature increase to a certain
value or the next command is received.
During test run, all buttons except
want to turn off the test run, please press
when the unit is in air purge mode, after you press
following page will be displayed:
Press ◄ ► to scroll the cursor to YES and press
test run will turn off.
10.7.12 SPECIAL FUNCTION
When it is in special function modes, the wired controller can
not operate, the page do not return to the homepage, and
the screen showed the page that special function runs, the
wired controller do not locked.
NOTE
During special function operating other functions
(WEEKLY SCHDULE/TIMER, HOLIDAY AWAY,
HOLIDAY HOME) can't be used.
132
EN
Go to
Before floor heating, if a large amount of water remains on
the floor, the floor may be warped or even rupture during
floor heating operation, in order to protect the floor, floor
drying is necessary, during which the temperature of the floor
should be increased gradually.
Press ▼ ▲ to scroll and press
During first operation of the unit, air may remain in the water
system which can cause malfunctions during operation. It
is necessary to run the air purge function to release the air
(make sure the air purge valve is open).
If PREHEATING FOR FLOOR is selected, after press
the following page will be displayed:
are invalid. If you
. For example,
, the
When the cursor is on OPERATE PREHEATING FOR
FLOOR, Use ◄ ► to scroll to YES and press