ZONE2
The type of zone2 end for cooling mode: 0=FCU (fan
2.13
C-EMISSION
coil unit), 1=RAD. (radiator), 2=FLH (floor heating)
3.1
HEAT MODE
Enable or disable the heating mode
The refresh time of climate related curves for
3.2
t_T4_FRESH_H
heating mode
The maximum ambient operating temperature for
3.3
T4HMAX
heating mode
The minimum ambient operating temperature for
3.4
T4HMIN
heating mode
3.5
dT1SH
The temperature difference for starting the unit (T1)
3.6
dTSH
The temperature difference for starting the unit (Ta)
3.7
t_INTERVAL_H
the start time interval of the compressor in HEAT mode
The setting temperature 1 of climate related curves
3.8
T1SetH1
for heating mode
The setting temperature 2 of climate related curves
3.9
T1SetH2
for heating mode
The ambient temperature 1 of climate related curves
3.10
T4H1
for heating mode
The ambient temperature 2 of climate related curves
3.11
T4H2
for heating mode
ZONE1
The type of zone1 end for heating mode: 0=FCU (fan
3.12
H-EMSSION
coil unit), 1=RAD. (radiator), 2=FLH (floor heating)
ZONE2
The type of zone2 end for heating mode: 0=FCU (fan
3.13
H-EMSSION
coil unit), 1=RAD. (radiator), 2=FLH (floor heating)
The delay time for water pump to stop after the
3.14
t_DELAY_PUMP
compressor stops
The minimum operating ambient temperature for
4.1
T4AUTOCMIN
cooling in auto mode
The maximum operating ambient temperature for
4.2
T4AUTOHMAX
heating in auto mode
WATER FLOW
Enable or disable the WATER FLOW
5.1
TBMP.
TEVP.:0=NON,1 =YES
Enable or disable the ROOM TEMP.:0=NON,1
5.2
ROOM TEMP.
=YES
Enable or disable the ROOM THERMOSTAT
5.3
DOUBLE ZONE
DOUBLE ZONE0=NON,1=YES
ROOM
The style of room thermostat 0=NON, 1 =MODE
6.1
THERMOSTAT
SET,2=ONE ZONE,3=DOUBLE ZONE
The temperature difference between T1S and T1 for
7.1
dT1_IBH_ON
starting the backup heater.
The time that the compressor has run before the
7.2
t_IBH_DELAY
first backup heater turns on
The ambient temperature for starting the backup
7.3
T4_IBH_ON
heater
The temperature difference between T1S and T1 for
7.4
dT1_AHS_ON
turning the additional heating source on
The time that the compressor has run before
7.5
t_AHS_DELAY
starting the additional heating source
The ambient temperature for starting the additional
7.6
T4_AHS_ON
heating source
IBH/AHS installation location PIPE LOOP=0;
7.7
IBH_LOCATE
BUFFER TANK=1
7.8
P_IBH1
Power input of IBH1
7.9
P_IBH2
Power input of IBH2
7.10
P_TBH
Power input of TBH
I he target outlet water temperature tor space
8.1
T1S_H.A_H
heating when in holiday away mode
The target outlet water temperature for domestic hot
8.2
T5S_H.A_DHW
water heating when in holiday away mode
PREHEATING
The setting temperature of outlet water during first
12.1
FOR FLOOR T1S
preheating for floor
12.3
t_FIRSTFH
The time last for preheating floor
136
EN
OMNIA M 3.2
Cod. 3QE47660 - Rev. 00 - 02/2022
22T÷30T
0
0
2
1
0
1
0.5
0.5
6
25
20
35
-15
-25
30
5
2
20
2
1
10
5
5
5
35
25
65
28
25
65
-5
-25
35
7
-25
35
1
0
2
2
0
2
2
0.5
20
25
20
29
17
10
17
1
0
1
0
0
1
0
0
1
0
0
3
5
2
10
30
15
120
-5
-15
30
5
2
20
30
5
120
-5
-15
30
0
0
0
0
0
20
0
0
20
2
0
20
25
20
25
25
20
25
25
25
35
72
48
96
1
/
1
/
0.5
hours
1
°C
1
°C
1
°C
1
°C
1
°C
1
°C
1
°C
1
°C
1
°C
1
/
1
/
0.5
MIN
1
°C
1
°C
1
/
1
/
1
/
1
/
1
°C
5
MIN
1
°C
1
°C
5
MIN
1
°C
0
°C
0.5
kW
0.5
kW
0.5
kW
1
°C
1
°C
1
°C
12
HOUR