System setting table:
MIG Mode
Symbol
Function parameter
P1
Restore factory settings (Select "1" to restore
factory settings)
P2
Calculating welding time
P3
Burn-back time after torch release for MIG
P4
Gas flow out time after welding in MIG mode
P5
Low wire feed speed (at start of welding, after
pressing torch trigger in MIG mode) *
P6
Burn-back voltage when the torch trigger is
released in MIG mode
P7
Gas outlet time before welding in MIG mode
P8
Circuit breaker for wire feeder peak current
P9
Manual wire feed speed*
*not available for these models
MMA Mode
Symbol
Function parameter
P1
Restore factory settings (Select "1" to
restore factory settings)
P2
Calculating welding time
P3
Enable (1) / Disable (0) VRD function in
MMA mode
P4
Arc force current in MMA mode (when
output voltage is below 14 V)
P5
Arc striking current in MMA mode
P6
Arc ignition time in MMA mode
TIG Mode
Symbol
Function parameter
P1
Restore factory settings (Select "1" to restore
factory settings)
P2
Calculating welding time
P3
Lift TIG current (the current value when the
electrode is in contact with the workpiece)
P4
Gas flow time in TIG welding *
*not available for these models
Default
Setting
value
range
0
0/1
0.0
0.0~999
200
0~400
0.2
0.0~2.0
2.0
2.0~10.0
12.0
10.0~18.0
5
0~30
0
0/1
5.0
2.0~16.0
Default
Setting
value
range
0
0/1
0.0
0.0~999
1
0/1
50
20~80
60
20~100
400
300~999
Default
Setting
value
range
0
0/1
0.0
0.0~999
28
20~50
2.0
1.0~10.0
Unit
-
Day
ms
S
m/min
V
0.01S
-
m/min
Unit
-
Day
-
A
A
ms
Unit
-
Day
A
S