H - Wire feed button and indicator light
I - Gas detection button and indicator light
Pressing causes gas to flow out; gas will stop flowing out automatically after
20 seconds. Pressing the button again within 20 seconds, will stop the gas
flow.
J - Button and indicator light for "synergic/separate" mode. - Lighting of the
lamp indicates that the "synergic" mode is on.
Synergic - In this mode, after setting the current/wire feed speed/workpiece
thickness, the system will automatically adjust the welding voltage.
Separate - In this mode, the current/wire feed speed/workpiece thickness
adjustment is not related to the voltage adjustment and requires a separate
setting.
K - Voltage/ Arc force (MIG/MMA)/ parameter set selection area.
ARC FORCE - this function enables adjustment of the welding arc
dynamics. Reducing the value of the function produces a soft arc and
a smaller depth of penetration, while increasing the value of the
function produces a deeper penetration and the possibility of short
arc welding.