Product description
The B71/PBX battery charger board provides the ROGER BRUSHLESS control units with the optimal power supply
voltage to allow the operation of the automated system, using a 12V
supplied by the factory.
The B71/PBX
analysing the operating values.
4
Version R2.20 updates
1. mixed mains/battery management functions added (FLEX60...FLEX90), to use the battery as much as possible even when mains voltage is
present
2. improved battery charge management for versions with transformer, always choosing the best energy source for recharging
3. increased the maximum manageable battery capacity, from 15Ah to 30Ah
4. increased the maximum battery charging current when using solar power: from 2.4 amps to 3.0 amps
5. improved internal time management, with the addition of time zone compensation (useful when using B74/BCONNECT that does not access
NTP servers, providing UTC time)
6.
7. added control functionality for new radio receiver accessory with RTCC (Real Time Clock Calendar) to be able to reactivate the control panel in
case of access during PowerSave time slot (future application)
8. added RTM BATTERY LIFE management mode which, by maintaining at 50% the battery charge threshold at which the control unit switches
manoeuvring (a solution which further reduces, a priori, the battery life)
5
MAINS POWER VOLTAGE
LEAD BATTERIES (not supplied)
MAX. MANAGEABLE BATTERY CAPACITY 30Ah
OPERATING TEMPERATURE
DEGREE OF PROTECTION
DIMENSIONS
WEIGHT (excluding the batteries)
PHOTOVOLTAIC PANELS (18V)
MAXIMUM SUPPLIED VOLTAGE UNDER
LOAD
MAXIMUM APPLICABLE VOLTAGE TO
THE PAN1/PAN2 TERMINALS
MINIMUM REQUIRED POWER
MINIMUM NUMBER OF
PHOTOVOLTAIC PANELS THAT CAN
BE CONNECTED PAN1 / PAN2 (parallel
connection) (**)
(*) 2 or 3 batteries 12V
B70/2ML, B70/2B, B70/1DC or EDGE1, B70/1DCHP, CTRL, CTRL/P)
(**) If two panels are connected, they must be of the same type (identical)
WARNING! The use of solar panels with a voltage higher than that indicated will lead to a malfunction of the charging
circuit, with the risk of damaging the circuit and the batteries.
5.1 Orientation of the photovoltaic panels
40°
SUD
52
B71/PBX24/BOX
B71/PBX24/BOX/115
20V~
2x 12V
4.5Ah
-20°C
IP66
310x120x390h
6,9
18V
22V
20W
1 (es: 1X20W)
12Ah will be installed, depending on the control unit to be powered (respectively B70/2DC,
The photovoltaic panel must be oriented by adjusting its inclination so that it is 40°
with respect to the horizontal plane:
- towards the SOUTH, if the place of installation is North of the equator (Boreal
hemisphere)
- towards NORTH, if the place of installation is South of the equator (Southern
hemisphere).
battery pack and photovoltaic panels, not
B71/PBX36/BOX
B71/PBX36/BOX/115
SEC1: 26V~
SEC2: 20V~
3x 12V
4.5Ah
30Ah
+55°C
-20°C
+55°C
IP66
310x120x390h
6,9
18V
22V
20W
1 (es: 1X20W)
B71/PBX/BOX
-
(*)
30Ah
-20°C
+55°C
IP66
310x120x390h
3,4
18V
22V
20W
2 (es: 2X30W)