11.18 Alarms menu
The indicated data is only indicative.
11.18.1
General alarms
GENERAL
BATT.CHARGER
BATTERY
PANEL
ENTER
LINE BLACKOUT
LINE LACK
HIGH VREG
OVER TEMPERATURE
ENTER
LINE BLACKOUT
TOTAL:
STATUS:
COUNTER:
ENTER
LINE BLACKOUT
TOTAL:
STATUS:
-----
COUNTER:
STOP
-----
ENTER
LINE BLACKOUT
TOTAL:
STATUS:
------
RESET
COUNTER:
------
ENTER
ESC
ESC
0
----
RUN
----
ESC
0
ESC
0
ESC
LINE BLACKOUT: Shows the number of blackouts
detected in the mains voltage.
STATUS:
ON: (if no mains power)
OFF: (if there is mains power)
LINE LACK: Shows the voltage surges (gaps) detected.
STATUS:
ON: (voltage hole detected in the last 60 seconds)
OFF: (regular mains voltage)
HIGH VREG: shows the number of overvoltage instances
detected in the internal voltage regulator (used by the
battery charger)
STATUS:
ON: (actual voltage too high)
OFF: (voltage within limits)
OVER TEMPERATURE: Displays the number of over-
temperature instances detected (exceeding the maximum
limit allowed by B71/PBX)
STATUS:
ON: (temperature too high)
OFF: (temperature within limits)
To see/modify the other functions, move onto the one
required (using the
and
same procedure.
STOP: interrupts the count
RESET: resets the count, keeping it at zero
Use the - key to go back in the sequence RESET > STOP
> RUN
RECOMMENDED SETTING: RUN
Return to the previous menu
keys) and repeat the
75