11.4
Voltage menu at output load - CONSULTATION ONLY
The indicated data is only indicative
EXAMPLE OF CONTROL UNIT POWERED BY BATTERY
OUT1
OUT2
21. 7°C
VREG
Temperature in the box
WARNING!!!
If the battery is delivering current and is discharged, the OUT1 and OUT2 outputs are disabled and "----" is displayed.
If the battery is delivering current and you are in the PowerSave time slot (par. 11.11), PSAV is displayed.
If "RTM BATTERY LIFE" is selected (par. 11.7) and the automation is turned on thanks to a command sent to B71/
PBX/RTCC, it displays BTLO (indicating that the batteries are low, and after this activation it will turn off the control
unit again)
EXAMPLE OF A CONTROL UNIT POWERED BY MAINS VOLTAGE
OUT1
OUT2
21. 7°C
FREQ
Temperature in the box
11.4.1
Examples of error alerts / alarms - Charge and output load regulator menu
ERROR ALERT/ALARM
ON
ALARM
V
V
OUT1
36.5V
OUT2
24.3V
24.3V
VREG
The OUT1 output supplies the ~ SEC1 voltage to the control
unit
SEC1
˜
The OUT2 output supplies the ~ SEC2 voltage to the control
unit
SEC2
˜
NOTE: OUT2 is not visualised in the case of installation for a
24V control unit (visualisation
50.0HZ
of OUT2 ----)FREQ indicates the network frequency detected.
DESCRIPTION
Battery electrically connected to the outputs OUT1 and OUT2.
The control unit is powered by battery
The battery is disconnected from the output OUT1 and OUT2.
The control unit is powered by the SEC1, SEC2 voltage or it is NOT powered
(activation of the safeguard mode for "low battery").
DESCRIPTION
Excessively high voltage detected on the internal voltage regulator (V)
Excessively low voltage detected on the internal voltage regulator (V)
Detected temperature too high for correct operation. When the maximum
temperature (+55°C) is exceeded, battery charging is deactivated and will
not start again until the temperature falls to 50°
Detected temperature too low for correct operation. When the temperature
falls below -25°C, battery charging is deactivated and will not start again
until the temperature rises to -20°
OFFSET error. Error in in charge control circuit calibration.
NOTE: the OFFSET alarm is critical and inhibits the automatic reset of the
battery charger functions. Contact Customer Service.
indicates the voltage that the battery supplies
to the control unit on output OUT1.
indicates the voltage that the battery supplies
to the control unit on output OUT2. If less than
24V
it means that too many accessories are
connected to the 24V
nit (overload).
NOTE: OUT2 is not visualised in the case of
installation
for
a
24V
(visualisation of OUT2 ----)
indicates the voltage used by the internal
voltage regulator
output of the control
control
unit
59