ENABLE
TARGET
ACTUAL
ENTER
Period of repetition of forced operation in battery mode: from 10 to 100 days (G).
Indicates the elapsed time. Once the target has been reached, a new discharge cycle starts.
Return to the previous menu
MAX: when the central unit is powered by battery, if the charge drops to 70% the central unit (outputs OUT1/OUT2) is
disconnected; the battery life is maximized. The control unit will be powered again if the charge reaches 75%.
MIN: when the central unit is powered by battery, if the charge drops to 50% the central unit (outputs OUT1/OUT2) is
disconnected; this deep discharge causes a reduction in battery life. The control unit will be powered again if the charge
reaches 65%. WARNING! Choose this setting only in the case of installations where frequent battery change is foreseen
(e.g.: seasonal installations)
RTM: it is the same as MIN, but in addition if B71/PBX has disconnected the central unit for low battery, the reception
then returns to switch off the central unit.
Indicates the current charge percentage.
Return to the previous menu
ON
10G
0G
ESC
MAINTENANCE ENABLED
TARGET: indicates how often the set discharge cycle will be
performed.
ACTUAL: indicates the elapsed time. Once the target is
reached, a new discharge cycle starts again.
Return to the previous menu
63