Electrical connections B71/PBX36/BOX - B71/PBX36/
BOX/115 - B71/PBX/BOX with 36V Brushless control units
(B70/1DCHP, EDGE1, CTRL, CTRL/P)
TERMINAL
DESCRIPTION
B71/PBX36/BOX: Connection to the 230V~ ± 10% mains power.
230 0
Fuse 5x20 T1A.
NOTE: not present in the B71/PBX/BOX version
L
N
B71/PBX36/BOX/115: Connection to the 115V~ ± 10% 60Hz mains power.
115 0
Fuse 5x20 T2A.
NOTE: not present in the B71/PBX/BOX version
L
N
Connection of SEC_1 to the secondary winding of the transformer (26V~), BLACK-BLACK wires
4
3
2
1
Connection of SEC_2 to the secondary winding of the transformer (19V~), BLUE-BLUE wires
NOTE: the connection is made by ROGER TECHNOLOGY in the factory.
NOTE: not connected in the B71/PBX/BOX version
SEC_1 SEC_2
Connect the OUT1 terminals to the SEC1 terminals of the control unit.
Connect the OUT2 terminals to the SEC2 terminals of the control unit.
Do not connect other devices to the OUT1, OUT2 terminals: they are dedicated to the brushless
ROGER control unit.
CAUTION: in installations with B70/1DCHP control unit, make sure the + terminal of OUT1 is
connected to the terminal 7 of the control unit.
In installations with CTRL or CTRL/P control unit, make sure the + terminal of OUT1 is connected
to the terminal 6 of the control unit.
NOTE
Connection to the 3x12V
BATTERY
The three batteries must be connected in series and must be of the same make and type.
Connect terminal 9 (-) to the NEGATIVE pole of the series (black cable) and the terminal 10 (+) to
9 10
Connection to photovoltaic panels. Maximum two panels can be connected, in which case they
must be identical. If only one panel with a power greater than 50W is connected, make a jumper
PAN1
PAN2
between the two "-" terminals (11-13) and one between the two "+" terminals (12-14) in order to
The voltage applied to each pair of terminals must not exceed 22V .
+
+
11 12 13 14
Connection connector to the ROGER WiFi B74/BCONNECT module.
The B74/BCONNECT module allows updating the device firmware and consulting certain
measurements performed via the WEB application.
WIFI
SERIAL expansion connector for accessories.
For future expandability, e.g. to connect B71/PBX/RTCC
ADTSER
WARNING!
• Before connecting the batteries, make sure jumper J1
page must display the code B71/PBX36. If there is an ERROR message, quickly change the battery voltage selection (SETTINGS menu
>> BATTERY >> VOLTAGE)
• Make sure (SETTINGS menu >> BATTERY >> CAPACITY) the capacity (in Ah) of the batteries used has been set. If it hasn't, the battery
charger won't work properly, and the batteries may get damaged)
For further information, refer to the solar panel installation manual B75 series.