2.4
Sensor Missing Alarm
The instrument enters the Sensor Missing alarm if the instrument detects
that an enabled sensor is not properly installed in the instrument or is not
functional.
For O
, CO, and H
2
the instrument is turned on and when leaving the Setup mode.
The combustible Sensor Missing feature is continuously monitored.
If a sensor is detected as missing, the following occurs:
"
SENSOR ERROR
The flag above the sensor detected as missing flashes on the display
Alarm sounds and lights flash.
If there is a sensor error at startup, the instrument shuts off in
60 seconds.
2.5
Monitoring Toxic Gases
The instrument can monitor the concentration of the following toxic gases in
ambient air:
Carbon Monoxide (CO)
Hydrogen Sulphide (H
The instrument displays the gas concentration in parts per million (PPM) or
3
mg/m
on the Measuring page until another page is selected or the
instrument is turned off.
Attention!
If an alarm is triggered while using the instrument, leave the
area immediately.
Remaining on site under such circumstances can cause serious
personal injury or death.
The instrument has four gas alarms:
HIGH Alarm
LOW Alarm
STEL Alarm
TWA Alarm
If the gas concentration reaches or exceeds the alarm set point, the instrument:
backlight turns on
a vibrating alarm triggers
displays and flashes the Alarm icon
icon
enters an alarm state.
GB
DECLARATION OF CONFORMITY CONTENTS
S sensors, the Sensor Missing feature is checked when
2
" displays
S)
2
(LOW alarm) or the Maximum icon
ALTAIR 4 - Operating Manual 10088160/00 Y-HLR
and either the Minimum
(HIGH alarm)
19